Standard Air Drying and Filtering Process
Compressed air is prefiltered prior to the desiccant dryer by a 1 micron solid particle particulate filter
and then by a oil removal filter [to 0.008 ppm (0.01 mg/m3)].
The wet, compressed air now enters the bottom of Tower 2 of the two dual towers filled with a bed of
activated alumina desiccant through the inlet switching
valve A. Inlet switching valve B is closed. Inlet valves A
and B are butterfly valves with double acting actuators.
The activated alumina adsorbs the moisture in the
compressed air as the air flows upward through Tower
2. Upflow drying protects the bed from water and heavy
contaminants by separating them from the air stream as they enter the tower. Cleanable, stainless steel, flow
diffusers on the inlet and outlet of the tower ensure even flow distribution through the bed-which avoids channeling.
The dry air exits the dryer through outlet check valve F. A FHT Series High Temperature afterfilter filters desiccant dust
particles to 1 micron in size at the dryer outlet.
FEATURES, BENFITS, OPTIONS
Standard Controller
Tower Status
Service Reminder
Heater on
Heater temperature
Desiccant bed temperature
Failure to switch
RS 232 port
NEMA 4 enclosure
Option E = Energy saving demand controller
Energy saving demand controller provides an integrated humidity/temperature sensor from the
on-line drying tower. Sensor “over-range” and “under-range” alarms. High humidity alarm.
Vacuum fluorescent text, 2 line 16 characters.
Highly visible in darkness or sunlight
English, Spanish, French languages
Automatic restart after power loss
Remote indication of alarm
Power on light
Heater on light
Tower status (drying, switchover, heat, cool, etc.)
Tower switch switchover, failure (low heater temp/high heater temp)
Dry Contacts (power, heater-on)
LED sensor over-range or under-range temp/humidity dew point
Service reminder
RS 232 port
NEMA4 enclosure
Option D = dewpoint monitor with energy saving demand controller
Digital dew point monitoring (text display)
All of the features of the Energy Saving Demand Controller
High dew point alarm
Option V
Insulate vessel shell and hot piping from heater to vessels
Option F1
Mounted Grade E prefilter and FHT afterfilter with drain valve on separate skid package.
Option F2
Mounted Grade E prefilter and FHT afterfilter with drain valve with block and by-pass valves on
separate skid package.
|