Hankison®'s Heatless Desiccant Dryers
The HHL Series
Utilizing twin towers filled with premium grade activated alumina, Hankison® Heatless dryers are available with three application specific control systems designed to meet the needs of specific industrial applications with economy and performance.
The HHL Series
Utilizing twin towers filled with premium grade activated alumina, Hankison® Heatless dryers are available with three application specific control systems designed to meet the needs of specific industrial applications with economy and performance.
Unit of Measure
Specifications
|
ISO 8573.1 Quality Classes
|
Precision Performance
|
Application Specific Designs
|
Controller Features
|
Selectable Purge Economizer Savings
|
Inlet Flow
|
Four Dew Point Options per ISO 8573-1 Air Quality Standards
|
Dedicated to Excellence
|
Note
Specifications
Series |
N/A HHL |
Brands |
N/A SPX® |
Inlet Flow Capacity at 100 psig (6.7 bar) Pressure |
N/A 60 scfm102 nm³/h |
Height |
N/A 61 in |
Width |
N/A 32 in |
Depth |
N/A 32 in |
Inlet Connection Size |
N/A 1 in |
Inlet Connection Type |
N/A NPT |
Outlet Connection Size |
N/A 1 in |
Outlet Connection Type |
N/A NPT |
Weight |
N/A 445 lb |
Note for Connections |
N/A BSP and DIN flanges available. |
Maximum Standard Working Pressure1 | N/A 150 psig10.5 bar |
Maximum Optional Working Pressure |
N/A 250 psig17.6 bar |
Minimum Operating Pressure |
N/A 60 psig120 psig150 psig250 psig4.2 bar8.4 bar10.5 bar17.6 bar |
Maximum Inlet Air or Ambient Air Temperature |
N/A 120 ºF49 ºC |
Pressure Drop at Rated Flow |
N/A ≤ 5 psi≤ 0.35 bar |
Available Voltage |
N/A 100 to 240 V |
Phase |
N/A 1 |
Frequency |
N/A 50 to 60 Hz |
Direct Current (DC) Voltage |
N/A 12 to 24 V |
Industry Standards/Certifications |
N/A ASME Approved CRN NEMA 4 |
Industry |
N/A Industries such as pharmaceutical manufacturing, laboratories, hospitals, microelectronics, food packaging, paper, glass and powder painting with low dew point requirements, utilize heatless desiccant air dryers. |
ISO 8573.1 Quality Classes
Dew Point |
N/A -100 ºF38 ºF-4 ºF-40 ºF-20 ºC3 ºC-40 ºC-73 ºC |
Remaining Moisture at Dew Point -100 ºF (-73 ºC) |
N/A 0.12 ppmw0.15 mg/m³ |
Remaining Moisture at Dew Point -40 ºF (-40 ºC) |
N/A 10 ppmw12 mg/m³ |
Remaining Moisture at Dew Point -4 ºF (-20 ºC) |
N/A 81 ppmw97 mg/m³ |
Remaining Moisture at Dew Point 38 ºF (3 ºC) |
N/A 610 ppmw730 mg/m³ |
Cycle Time for ISO Quality Class 1 |
N/A 4 min. Fixed |
Cycle Time for ISO Quality Class 2 |
N/A 10 min. Fixed |
Cycle Time for ISO Quality Class 3 |
N/A 16 min. Fixed |
Cycle Time for ISO Quality Class 4 |
N/A 24 min. Fixed |
Precision Performance
Industry-Leading Design |
N/A
|
Integrated Filtration |
N/A
|
Precision AccuShift™ Switching Valves |
N/A
|
Engineered-to-Order Options |
N/A
|
Safety Built to Code |
N/A
|
Application Specific Designs
How it Works |
N/A
|
Controller Features
Controller Features |
N/A
|
Selectable Purge Economizer Savings
Selectable Purge Economizer Savings |
N/A
HHL Series provides user selectable energy savings with tailored drying cycles designed to match your peak air demands. Reducing the amount of time the dryer spends purging in the regeneration cycle can save energy. Eight settings (0% to 70% in 10% increments) are furnished for users to lower the purge to match reduced air loads on the dryer. Each energy saving setting has an LED light which will illuminate when it is selected. Simply flip the switch to select the desired energy saving setting. In addition, this state-of-the-art controller offers four pressure dew point settings to further tune your savings and adapt the system to your environment. |
Inlet Flow
Inlet Flow |
N/A Inlet flow capacities are established in accordance with CAGI (Compressed Air and Gas Institute) standard ADF-200: Inlet air pressure 100 psig (6.7 barg), inlet temperature saturated at 100 ºF (38 ºC). To determine inlet flow at pressures other than 100 psig (6.7 barg), multiply inlet flow at 100 psig (6.7 barg) from Product Specifications by the corresponding multiplier. |
Four Dew Point Options per ISO 8573-1 Air Quality Standards
Four Dew Point Options per ISO 8573-1 Air Quality Standards |
N/A Specifying a pressure dew point is not simple work for an engineer. Hankison® Heatless dryer designs allow you to optimize performance and dew points in the field to adapt to your environment and meet the following ISO 8573-1 Classes of air quality. |
Dedicated to Excellence
Dedicated to Excellence |
N/A
Since 1948, compressed air users around the world have relied on Hankison® to provide innovative compressed air treatment solutions for critical applications. Hankison® maintains a long standing reputation for manufacturing products that deliver superior performance, time proven reliability and optimal energy savings. Hankison® today is the preferred choice for providing clean, dry compressed air for the most challenging industries. |
- 1 Units with higher Maximum Working Pressures are available.