Inlet Flow capacities have been established at an inlet pressure of 100 psig (7 kgf/cm2), and a saturated inlet temperature at 100°F (38°C). To determine maximum inlet flow at other conditions, multiply the inlet flow from the Specifications Table by the multiplier from Table 1 that corresponds to your operating conditions.
Dew Point: Outlet pressure dew point at rated inlet conditions of 100 psig (7 kgf/cm2) and 100°F (38°C) and 70°F (21°C) atmospheric dew point is -40°F (-40°C). Dew point varies slightly at other conditions. Consult factory to determine exact outlet pressure dew point at your operating conditions.
Outlet Temperature at normal rated conditions (after temperature spike) is 127°F (53°C). Outlet temperature varies depending on inlet temperature and pressure.
Consult factory to determine exact outlet temperature at your operating conditions.
Available voltages: 460V/3ph/60Hz, NEMA 4 enclosure
Non-standard conditions contact customer service.
Specifications
Flow |
N/A 1500 scfm |
Heater Rated Output |
N/A 28 kW |
Blower Power |
N/A 10.1 hp |
Height |
N/A 116 in |
Width |
N/A 80 in |
Length |
N/A 93 in |
Inlet/Outlet Connection |
N/A 3" ANSI Flg |
Repl. Desiccant |
N/A 1259 lb |
Weight |
N/A 5359 lb |
Operating Parameters
Maximum Working Pressure |
N/A 150 psig |
Minimum Working Pressure |
N/A 60 psig |
Inlet Air at 100°F ±2°F |
N/A 100 ±2 psig |
Ambient Temperature |
N/A 80°F ±5°F |
Ambient Dew Point Temperature |
N/A 70 °F |
Inlet Pressure Dew Point |
N/A 100 °F |
Outlet Pressure Dew Point |
N/A -40 °F |
Maximum delta P |
N/A 5 psid |
Drying Time |
N/A 4 hours |
Inlet Air Pressure |
N/A 60–150 psig |
Inlet Air Temperature |
N/A 40–120 °F |
Features
N/A
1. Reliable and Durable Air Flow Control Components
|
Process Designs
N/A
|