DPB Series - Global Air Treatment Dryers (500 – 4300 scfm)
Air Treatment Filters & Accessories
The DPB Series process design offers the end user the opportunities to significantly reduce the energy costs associated
with achieving a reliable -40°F (-40°C) pressure dew point. This is achieved by eliminating or reducing purge air
requirements (compressed air utilized to regenerate desiccant beds) typical of other desiccant dryer designs.
Inlet Flow capacities have been established at an inlet pressure of 100 psig (7 kgf/cm2), and a saturated inlet temperature at 100°F (38°C). To determine maximum inlet flow at other conditions, multiply the inlet flow from the Specifications Table by the multiplier from Table 1 that corresponds to your operating conditions.
Dew Point: Outlet pressure dew point at rated inlet conditions of 100 psig (7 kgf/cm2) and 100°F (38°C) and 70°F (21°C) atmospheric dew point is -40°F (-40°C). Dew point varies slightly at other conditions. Consult factory to determine exact outlet pressure dew point at your operating conditions.
Outlet Temperature at normal rated conditions (after temperature spike) is 127°F (53°C). Outlet temperature varies depending on inlet temperature and pressure.
Consult factory to determine exact outlet temperature at your operating conditions.
Available voltages: 460V/3ph/60Hz, NEMA 4 enclosure
Non-standard conditions contact customer service.
Inlet Flow capacities have been established at an inlet pressure of 100 psig (7 kgf/cm2), and a saturated inlet temperature at 100°F (38°C). To determine maximum inlet flow at other conditions, multiply the inlet flow from the Specifications Table by the multiplier from Table 1 that corresponds to your operating conditions.
Dew Point: Outlet pressure dew point at rated inlet conditions of 100 psig (7 kgf/cm2) and 100°F (38°C) and 70°F (21°C) atmospheric dew point is -40°F (-40°C). Dew point varies slightly at other conditions. Consult factory to determine exact outlet pressure dew point at your operating conditions.
Outlet Temperature at normal rated conditions (after temperature spike) is 127°F (53°C). Outlet temperature varies depending on inlet temperature and pressure.
Consult factory to determine exact outlet temperature at your operating conditions.
Available voltages: 460V/3ph/60Hz, NEMA 4 enclosure
Non-standard conditions contact customer service.
Unit of Measure
Items |
/Asset/DPB-Series_Features.JPG DPB0500 DPB Series - Global Air Treatment Dryers (500 – 4300 scfm) |
/Asset/DPB-Series_Features.JPG DPB0600 DPB Series - Global Air Treatment Dryers (500 – 4300 scfm) |
/Asset/DPB-Series_Features.JPG DPB0750 DPB Series - Global Air Treatment Dryers (500 – 4300 scfm) |
/Asset/DPB-Series_Features.JPG DPB0900 DPB Series - Global Air Treatment Dryers (500 – 4300 scfm) |
/Asset/DPB-Series_Features.JPG DPB1050 DPB Series - Global Air Treatment Dryers (500 – 4300 scfm) |
|||||
Flow | N/A 500 scfm | N/A 600 scfm | N/A 750 scfm | N/A 900 scfm | N/A 1050 scfm | |||||
Heater Rated Output | N/A 10 kW | N/A 12 kW | N/A 14 kW | N/A 16 kW | N/A 19 kW | |||||
Blower Power | N/A 2.2 hp | N/A 3.4 hp | N/A 2.9 hp | N/A 2.7 hp | N/A 3.7 hp | |||||
Height | N/A 105 in | N/A 108 in | N/A 114 in | N/A 114 in | N/A 113 in | |||||
Width | N/A 53 in | N/A 55 in | N/A 60 in | N/A 60 in | N/A 64 in | |||||
Length | N/A 70 in | N/A 71 in | N/A 83 in | N/A 83 in | N/A 84 in | |||||
Inlet/Outlet Connection | N/A 2" NPT | N/A 2" NPT | N/A 3" ANSI Flg | N/A 3" ANSI Flg | N/A 3" ANSI Flg | |||||
Repl. Desiccant | N/A 354 lb | N/A 453 lb | N/A 590 lb | N/A 590 lb | N/A 710 lb | |||||
Weight | N/A 1866 lb | N/A 2111 lb | N/A 2456 lb | N/A 2472 lb | N/A 2981 lb | |||||
Maximum Working Pressure | N/A 150 psig | |||||||||
Minimum Working Pressure | N/A 60 psig | |||||||||
Inlet Air at 100°F ±2°F | N/A 100 ±2 psig | |||||||||
Ambient Temperature | N/A 80°F ±5°F | |||||||||
Ambient Dew Point Temperature | N/A 70 °F | |||||||||
Inlet Pressure Dew Point | N/A 100 °F | |||||||||
Outlet Pressure Dew Point |
N/A -40 °F | |||||||||
Maximum delta P | N/A 5 psid | |||||||||
Drying Time | N/A 4 hours | |||||||||
Inlet Air Pressure | N/A 60–150 psig | |||||||||
Inlet Air Temperature | N/A 40–120 °F | |||||||||
Features |
N/A
1. Reliable and Durable Air Flow Control Components
2. Durable and Eficient Blower 3. Heater Design for Long Life 4. Insulation Reduces Heater Size 5. Large Desiccant Beds Ensure Consistent Dew Points 6. Quality Tower Design |
|||||||||
Process Designs |
N/A
Standard Air Drying and Filtering Process FEATURES, BENFITS, OPTIONS Standard Controller Option E = Energy saving demand controller Option D = dewpoint monitor with energy saving demand controller Option V Option F1 Option F2 |
|||||||||
|